EWR08ED – Walk-In Oven

Operating Temperature 

150°F (66°C) to 800°F (427°C)

Heating Medium

Electric, low watt density Incoloy® heaters provide years of trouble free service.  Standard heater bank assemblies are installed in high velocity ductwork to maximize heat transfer.

Airflow Pattern

Dual (Combination) Airflow: Hot air is supplied from both of the side walls and returned through a top plenum.

Input Voltage

Standard: 480/3/60. Please consult factory for additional options.

Control System

LEWCO’s standard control package includes a single set-point process temperature controller and redundant high-limit controller. Circulation fan(s) and exhaust fan(s) include air proving circuits that are electrically interlocked with the heating circuit. All controls are housed in a NEMA 12 enclosure employing a full voltage lockable disconnect switch. Ovens operating at or above 800°F include a zero speed switch for fans.  Controls are wired to NFPA 70 and 79 electrical standards in our own UL508A certified panel shop. Independent third party inspections available.

Optional:

Door Switch
Disables heat when door is opened on electrically heated ovens; holds burner at low fire on fuel-fired ovens.

Batch Timer
Infinitely adjustable up to 100 hrs., includes illuminated On/ Off switch to indicate timed operation and audible alarm when time has elapsed.

Ramp/ Soak Controller
Programmable ramp/ soak temperature controller with capability to store different recipes with multiple segments.

Chart Recorder
Single pen circular paper chart recorder for continuous monitoring of temperature data. Comes with (1) Type “J” thermocouple input.

PLC
Programmable Logic Controller for processes with numerous inputs and outputs; or requiring automation of material handling equipment. The PLC can also allow for Ethernet connectivity for remote system monitoring.

Touchscreen HMI
Human Machine Interface provides the operator easy access and control of different parts of the equipment. Allows real time monitoring and provides feedback of the process in a visual, easy to read format.

Composite Curing Controls:

Data Logger: Multiple input digital data logger continuously records temperature and other process data. Allows downloading of digital data files through USB or Ethernet connection. Data can also be viewed on a full color display or on a web server when connected to a network.

Thermocouple Jacks: Thermocouple jack panel for high-temperature Type “J” thermocouples, located inside the oven. Includes wiring to data logger if purchased.

Vacuum Ports: ½” NPT thru-wall vacuum ports, each with vacuum rated manual ball valve and indicating gauge. All ports are connected to a 1” NPT header.

Vacuum Pump: Includes motor starter circuit and connection to vacuum header pipe.

Model (NFPA Class B) Overall Dimensions Door Swing Radius Workspace Dimensions Heater Bank
(kW)
Circulating Fan
(CFM)
Motor
(HP)
Air Changes per Minute Exhaust Fan Capacity (CFM) Exhaust Motor (HP) Solvents per Batch
(Gals.)
Ships Fully Assembled
“W “D “H “W “D “H
EWR08ED-48-48-60
86 110 77 24″ 48 48 60 54 2,000 1 1/2 25.00 N/A N/A 0 Yes
EWR08ED-48-48-72
88 110 89 24″ 48 48 72 63 2,500 2 26.04 N/A N/A 0 Yes
EWR08ED-48-48-96
90 114 113 24″ 48 48 96 72 3,500 3 27.34 N/A N/A 0 Yes
EWR08ED-48-72-72
90 144 89 24″ 48 72 72 72 4,000 3 27.78 N/A N/A 0 Yes
EWR08ED-48-72-96
94 148 113 24″ 48 72 96 81 5,000 3 26.04 N/A N/A 0 Yes
EWR08ED-48-96-72 94 172 89 24″ 48 96 72 81 5,000 3 26.04 N/A N/A 0 Yes
EWR08ED-48-96-96 98 178 113 24″ 48 96 96 99 7,000 5 27.34 N/A N/A 0 Yes
EWR08ED-60-60-60
102 126 77 30″ 60 60 60 63 3,500 3 28.00 N/A N/A 0 Yes
EWR08ED-60-60-72 102 132 89 30″ 60 60 72 72 4,000 3 26.67 N/A N/A 0 Yes
EWR08ED-60-60-96 106 136 113 30″ 60 60 96 81 5,000 3 25.00 N/A N/A 0 Yes
EWR08ED-60-72-72 104 148 89 30″ 60 72 72 81 4,500 3 25.00 N/A N/A 0 Yes
EWR08ED-60-72-96 108 154 113 30″ 60 72 96 90 6,000 3 25.00 N/A N/A 0 Yes
EWR08ED-60-96-96 114 178 113 30″ 60 96 96 108 8,000 5 25.00 N/A N/A 0 Yes
EWR08ED-72-72-72
118 154 89 36″ 72 72 72 81 5,500 3 25.46 N/A N/A 0 Yes
EWR08ED-72-72-96 126 154 113 36″ 72 72 96 99 8,000 5 27.78 N/A N/A 0 Yes
EWR08ED-72-96-96 130 185 113 36″ 72 96 96 117 10,000 7 1/2 26.04 N/A N/A 0 Yes
EWR08ED-72-120-96
134 214 113 36″ 72 120 96 153 12,000 7 1/2 25.00 N/A N/A 0 Yes

Note: Sizes are approximate. LEWCO, Inc. reserves the right to change specifications without notice.

Standard oven construction includes a 16 gauge aluminized steel interior with a 18 gauge cold rolled steel exterior. Heat loss is minimized by a unique wall design featuring a welded inner shell and a completely isolated outer frame and covers.

Doors

Heavy-duty doors on an isolated door frame minimize heat loss. Wire core gaskets create a tight seal for efficient heating. Standard doors are bi-parting swing at one end and include explosion venting latches.

     Standard Options:

  • Vertical lift guillotine door
  • Door windows

Flooring

Standard ovens operating at or above 650°F include an insulated base (100 p.s.f. max)

     Standard Options:

  • Insulated with (1) pair inverted angle track
  • Insulated with (1) pair 6” wide wheel guides

LEWCO industrial ovens are designed and manufactured to industry standards. Our engineers regularly work to keep updated with the latest revisions in industry codes. If there is a specific industry standard or code compliance that you require for your process heating application, please contact one of our highly knowledgeable applications engineers to learn how LEWCO can help!

About NFPA 86

The National Fire Protection Association’s standard, NFPA 86, documents the guidelines for the safe operation of industrial ovens and furnaces. All LEWCO ovens are designed and manufactured to meet the requirements of this standard. Oven and furnaces in which flammable volatiles or combustible materials are present in the work space are classified by NFPA 86 as “Class A.” Similarly, ovens and furnaces in which no flammable volatiles or combustible materials are present are classified as “Class B.” Due to the risk of fire or explosion, NFPA 86 requires specific safety equipment for all Class A ovens and furnaces. Fuel gas-fired ovens and furnaces also require safety equipment.

  • Powered exhaust of capacity determined by maximum solvent loading.
  • Explosion relief of adequate area determined by oven or furnace workspace volume.

Industry Standards